Affected product: Supercal 5, Superaqua 1, Supercom P.
Improvement: Improved the low level NFC communication layer to enhance reliability and stability.
Affected product: Supercom P.
Fixed bug: Fixed an issue where Inputs could no longer be programmed correctly.
Affected product: Supercal 5.
Fixed bug: Fixed an issue where Inputs could no longer be programmed correctly.
Affected product: Superprog.
Improvement: Added a Release Notes link to the Help menu for easier access to version information and updates.
Affected product: Supercal 5.
Improvement:
Affected product: Superprog.
Bug fixed: Fixed an issue where Superprog could occasionally display the Updates list showing an update to the same version already installed. The update notification logic has been corrected to prevent false update prompts.
Affected product: Superprog.
Bug fixed: Fixed an issue where changing the setting in a language other than English caused the configuration copy menu to disappear after restart. The application was saving the translated value instead of the underlying enumeration value, leading to an initialization error.
Affected product: Supercal 5.
New feature: Added support in Superprog for Supercal 5 devices running firmware v1.1.0, including new features.
Affected product: Supercal 5U
New feature: Added support for the new Supercal 5U (Ultrasonic) device.
Affected product: Supercal 5.
New feature: Added a button to simulate a volume (200 pulses) in the “Metrology-Verify” menu.
Affected product: Superprog.
Update: Introduced a new splash screen.
Affected product: Supercal 5.
Improvement: Updated Superprog behavior for Supercal 5i devices with certification:
Note: Commissioning date = 01.01.2000 = never sealed
Affected product: Superprog and WEPROG.
Improvement: Unified the Sontex and Wehrle versions (WEPROG) into a single Superprog Win application, streamlining maintenance and user experience.
Affected product: Superprog.
Improvement: Special warnings, previously integrated only for the Supercal 5 LoRa module, have now been extended to other Supercal 5 screens and Supercom P screens. This integration into the new framework improves their visibility and consistency in the user interface.
Affected product: Superprog.
Improvement: Superprog can now suggest corrections for invalid configuration values. Users can choose to apply automatic corrections with a right click on red text of the left menu or handle specific issues manually.

Affected product: Superprog.
Improvement: The history view now indicates histories that are available on the device but have not yet been read. Where supported by the device (e.g., Supercal 5, Superaqua 1), users can also choose to read subsets of these histories with a right click, improving data visibility and management.

Affected product: Superaqua 1.
Improvement: For values such as Superaqua 1 volume, the node can no longer be expanded, as it contains only a single underlying item. This simplifies the user interface and avoids unnecessary node expansion.

Affected product: Supercal 5.
Fixed bug: Certification field in Device menu was sometimes inconsistent. This has been resolved.
Affected product: Supercal 5.
Bug fixed: The Special Liquids update was failing consistently. The update process has been corrected and now completes successfully.
Affected product: Supercom W1/W2.
Bug fixed: Configuration copy now works correctly depending on the radio type. If the source and target devices have the same radio type (e.g. W1-R → W1-R), the copy works with all parameters enabled. If the radio type is different, the copy fails unless the radio type parameter is disabled (e.g. W1-R → W1-O).
Affected product: Superprog Windows.
Improvement: The configuration copy dialog now reuses the connection settings from the main window if a device has been detected, even when the configuration file is for a different device type (if supported). The previous behavior—using separately saved connection settings—remains as fallback when no compatible device has been detected.
Affected product: Superprog Windows.
Improvement: The configuration copy dialog now remembers the last selected Copy from option and restores it the next time the dialog is opened. This setting is saved only when a device has been detected and can also be edited in the configuration editor.
Affected product: Supercom P.
Bug fixed: Fixed an issue where Configuration Copy for Supercom P devices was no longer working.
Affected product: Superprog Windows.
Bug fixed: During configuration copy, the category selection was reset based on the target device instead of keeping the user’s selection. The selection now always respects the user’s choice; if incompatible with the target, the write operation fails.
Affected product: Superaqua 1.
New feature: Added the ability to store and read 480 daily volume values, if the feature is enabled on the device.
Usage:

Affected product: Superprog.
New feature: A Spanish language option has been
added and can now be selected from:
Options → Configurations → General Configurations → Languages.
This allows users to operate the application fully in Spanish.
Affected product: Superprog.
Improvement: Improved the consistency of progress bar displays when reading or writing parameters to a device. Progress bars are now displayed in the same order in both the pop-up window and the bottom-right corner.
Affected product: Supercom P.
Improvement: Added support for an installation protocol (.pdf) for the Supercom P device. This allows users to generate and export a clear, standardized installation report in PDF format.
Affected product: Superlink C.
Improvement: Added support for a dedicated installation protocol (.pdf) for the Superlink C device. This allows users to generate and export a clear, standardized installation report in PDF format.
Affected product: Superprog Window.
Improvement: The Configuration Copy menu has been completely redesigned to improve usability and make it more userfriendly.

Affected product: Supercal 5.
Improvement: Previously, if a device had been programmed (e.g., via production tools or LoRa Downlink) with parameter values outside the officially permitted limits, Superprog would display only the nearest valid minimum or maximum value. With this improvement:
Note: This enhancement currently applies only to LoRaWAN module parameters.
Affected product: Superprog.
New feature: An Italian language option
has been added and can now be selected from:
Options → Configurations → General Configurations → Languages.
This allows users to operate the application fully in Italian.
Affected product: Superprog.
New feature: A French language option has
been added and can now be selected from:
Options → Configurations → General Configurations → Languages.
This allows users to operate the application fully in french.
Affected product: Superaqua 1.
Bug fixed: Resolved an issue where negative volume values from Superaqua 1 devices were not displayed in Superprog. These values are now correctly shown in the interface.
Affected product: Supercom P.
Bug fixed: Fixed an issue where totalizer values for Supercom P were incorrectly displayed in the main menu of Superprog. The values now appear accurately.
Affected product: Supercal 5 - Radio Sontex.
Bug fixed: Resolved an issue that prevented users from modifying the telegram content for Sontex Radio devices. Specifically, it was not possible to edit the "Default frames" under Device → Dataset → Sontex Radio. This functionality is now working correctly again.
Affected product: Supercal 5.
Bug fixed: We have resolved an issue where tariff values displayed on the Supercal 5 could occasionally appear incorrect. This behavior was dependent on the selected unit and resolution settings. The values are now displayed accurately across all configurations.
Affected product: Supercom W1L/W2L.
Bug fixed: Fixed incorrect minimum LoRaWAN transmission interval values.
Affected product: Superprog.
Bug fixed: Fixed an issue where no error or warning message was displayed in Superprog when attempting to write a parameter with an incorrect installer password.
Affected product: Supercom W1/W2.
Bug fixed: Resolved an issue that prevented users from entering decimal values when preconfiguring the initial volume of Supercom W1/W2 radio modules.
Previously, if the Windows language settings used a comma (",") as the decimal separator, it was not possible to enter digits after the comma in the volume field. This has now been fixed, and the input behaves correctly according to the system's regional settings.
Affected product: Supercal 5.
Bug fixed: Fixed an issue where changing the percentage of a special liquid by typing directly into the field (instead of using the spin edit arrows) would not correctly program the value when clicking the "Program" button.
Affected product: Superaqua 1.
Bug fixed: Fixed an issue that prevented writing the Exit Storage Mode Volume parameter in SQ1 devices.
Affected product: Supercal 5.
Bug fixed: Fixed an issue where changing the
unit of energy or volume in Superprog could result in
values that exceeded the displayable range on the device LCD. In
such cases, the LCD would incorrectly show
"-------.--".
The system now checks whether the converted value fits within the display limits. If it exceeds the maximum, Superprog will automatically program the maximum allowed value (99999.999) instead.
Affected product: Supercal 5.
Bug fixed: Fixed an issue where the popup menu would not disappear when locking and unlocking the display of the Supercal 5 (shift+”F11” and “F11”).
Affected product: Superprog.
Bug fixed: After detecting a device, the left-side menu was sometimes incorrect or incomplete, requiring a second detection. This issue has now been resolved.
Affected product: Superprog.
Bug fixed: The main menu sometimes failed to display values after device detection, requiring a second detection to view them. This issue has now been resolved, and values are displayed correctly after the first detection.
Affected product: Supercal 5.
Improvement: You can now export values from the “Verify screen” with configurable filename formats for CSV files. This functionality aligns with the existing configuration available on the Installation Protocol screen and is designed to support the same list of replaceable tags. Supported tags include:
Manufacturer (SON)
Fabrication/Identification number of the device
Current date (yymmdd)

Affected product: Supercom W1-L.
New feature: A new field now displays the device's current operation mode. Users can also manually force the SMW1-L back into storage mode for greater control."
Affected product: Supercal 5.
Improvement: Corrected the alignment in the "Installation Protocol" window. The content was previously aligned to the left instead of the correct right alignment.
Affected product: Sontex 878.
Maintenance: The Sontex 878 has been removed from Superprog as it is now fully managed in Prog6 (version ≥ V1.6.0.0). Previously, only LoRaWAN parameter configuration was handled in Superprog, requiring users to switch between tools. With this change, all configurations for Heat Cost Allocators can now be performed in a single tool (Prog6), simplifying the process and improving user experience.
Affected product: Superaqua 1.
Bug fixed: Resolved an issue where the timezone field was not correctly calculated and displayed after a reading in summer.
Affected product: Superlink C.
Improvement: We have streamlined the UI of Superlink C by removing unnecessary fields. This results in a cleaner, more focused interface with improved legibility.
Affected product: Superprog.
Improvement: Superprog now verifies that the device is the same as the one initially detected before writing, reducing the risk of misconfiguration.
Affected product: Supercal 5.
Improvement: Enhanced the layout and formatting of the PDF “Installation Protocol”, ensuring a clearer, more structured document.
Affected product: Supercal 5 LoRaWAN.
Improvement: The Superprog now enables a reduced minimum sending interval of 15 minutes for all spreading factors, but only when a Supercal 5 LoRaWAN device is detected with a 230VAC or 12-24ACDC power supply. This allows for more frequent data transmission for mains-powered devices, where power consumption is not a concern. Battery-powered devices remain unaffected and continue to use the standard sending intervals.
Affected product: Superaqua 1.
Improvement: The "Identification number" field has been renamed to "Fabrication number" in the Superaqua 1 device to better reflect the intended meaning and usage.
Affected product: Superprog.
Improvement: Enhanced PDF Installation Protocol Features
Affected product: Superaqua 1.
Improvement: Updated Warnings and Errors in Superaqua 1 to match the specifications outlined in the datasheet. This improves clarity and consistency with the official documentation.
Affected product: Superprog.
Improvement: Trying to read an unsupported device version? No worries! A friendly pop-up will now let you know and kindly suggest updating your Superprog to get back on track.
Affected product: Supercal 5.
Bug fixed: We resolved an issue where negative power values were incorrectly displayed as 0. The system now accurately reflects negative power values as intended.
Affected product: Superaqua 1.
Bug fixed: We fixed an issue where the pop-up window did not close automatically after completing the "Clear Fraud" command in Alarms menu. This behavior has now been resolved.
Affected product: Supercom P.
Bug fixed: An issue causing the Superprog to freeze when programming a Supercom P-L has been resolved. The dialog now completes successfully, ensuring reliable and efficient programming functionality.
Affected product: Supercal 5 LoRaWAN.
Bug fixed: Fixed an issue where the “Join Status” and “Uplink Status” values were displayed incorrectly, with the values being switched in the LoRaWAN module. The correct statuses are now displayed in their respective fields.
Affected product: Supercal 5.
Bug fixed: Fixed an issue where Wire M-Bus communication would fail if the required filter file was missing or corrupted. The system now properly handles the absence or corruption of the filter file, ensuring communication continues without issues even when the filter does not exist.
Affected product: Superaqua 1.
Bug fixed: Fixed an issue where the monthly values in the Superaqua 1 device were rounded to fewer decimal places than required. The device now correctly displays 3 digits after the decimal separator. For example, 0.177 m3 will now correctly display as 0.177 m3 instead of being rounded to 0.180 m3.
Affected product: Supercom P.
Bug fixed: Fixed an issue where the initial value of counter inputs could not be modified any more. Users can now change the initial value as expected.
Affected product: Superprog.
Fixed an issue where the device time was not set despite the checkbox being activated in the OSG settings. The command is now correctly sent and executed.
Affected product: Superaqua 1.
Bug fixed: Fixed an issue where Superprog would get stuck and fail to execute properly after exiting sleep mode of Superaqua 1. The freeze has been resolved, ensuring smooth functionality.
Affected product: Superaqua 1 LoRaWAN.
Bug fixed: Fixed an issue where the LoraWAN payload was not copied during the configuration copy process. The payload is now correctly copied along with other configuration settings.
Affected product: Supercal 5.
Bug fixed: Resolved an issue where the Supercal 5 “History checkbox” was not working as expected. The checkbox now correctly triggers the read history function.

Affected product: Supercal 5.
Bug fixed: Resolved an issue where special liquids programmed in Supercal 5 could not be read using Superprog. The user interface now refreshes correctly after programming.
Affected product: Supercom P.
Bug fixed: Fixed an issue where errors and warnings were not displayed correctly on the main screen. Enhanced the layout of the device screen for improved readability and navigation.
Affected product: Supercom W1-L/W2-L.
Bug fixed: The “Change Installer Password” command was not visible in the “Device” menu, this has been corrected.

Affected product: Supercal 5.
Bug fixed: Unfortunately, when the Supercal 5 had negative temperatures, these were not displayed in the Superprog. This has now been corrected.
Affected product: Supercom W2-L.
Bug fixed: If you set these LoRa parameters at the same time (the confirm mode, RTC sync and join only SF12), not all parameters are written correctly, this has been fixed.
Affected product: Supercom W2-L.
Bug fixed: If you change the volume or the water meter ID or the set day and then write nothing happens, this has now been fixed.
Affected product: Supercal 5
Bug fixed: The field “Frequency” is empty after a detection, the problem has been corrected.

Affected product: Supercal 5
Bug fixed: The list of deviation curves in the “Metrology” menu was no longer visible, the problem has been corrected.
Affected product: Supercal 5
Bug fixed: Communication via the wired M-Bus was no longer working (via primary or secondary address), the problem has been corrected.
Affected product: Supercal 5
Bug fixed: The field “Compensation method” is empty after a detection, the problem has been corrected.

Affected product: Supercom W2-L.
New feature : We are pleased to announce that our latest product Supercom W2-L is now officially available in the Superprog software.
Affected product: Supercom W2-R.
New feature: We are pleased to announce that our latest product Supercom W2-R is now officially available in the Superprog software.
Affected product: Supercal 5 - LoRaWAN module
New feature: We’ve added a configuration copy function for SC5 LoRaWAN modules. This allows you to easily copy all configured settings from one module to another, streamlining the setup process.
Affected product: Superaqua 1.
New feature: Users now have the ability to disable the LoRaWAN radio on SQ1 devices. This addition gives users more control over their SQ1 LoRaWAN devices and allows for better resource management
Affected product: Supercal 5.
New feature: The "Check for Upgrades" function now also checks for updated special liquids. This enhancement allows new special liquids to be added and installed independently of software version updates.
Affected product: Superaqua 1, Supercom W1/W2, Superlink C.
New feature: We’ve extended the configuration copy function to the SQ1, Supercom W1/W2, and Superlink C products. You can now easily copy all configured settings from one module to another, streamlining the setup process across these devices.
Affected product: Superaqua 1, Supercom W1/W2.
New feature: We’ve implemented a PDF creation and export function for installation protocols of SQ1, Supercom W1, and W2 devices. You can now easily generate and export installation reports in customizable PDF format.
Affected product: Superaqua 1.
Improvement : We've introduced a new field named “Production NFI” (Internal Fabrication Number) for SQ1 devices. This addition provides better tracking and internal identification for each device and improving support processes.

Affected product: Supercom W1-L
Improvement: New Volume History Fields: Added new fields that record volumes stored 1 to 4 hours ago. These fields are now selectable and can be added to LoRaWAN payloads.

Affected product: Superaqua 1.
Improvement: The Metrology menu has been reorganized for improved navigation and ease of use.
Affected product: Superprog
Improvement: The configuration menu under Options -> OSGi Configurations has been redesigned with a new layout that offers better readability and a more intuitive structure. These changes aim to provide a cleaner, more user-friendly interface, making it simpler for users to manage and configure their settings.
Affected product: Supercom P-L.
Improvement: The setting for enabling or disabling wired M-Bus power is now saved in the configuration file. This ensures that the chosen setting persists across device restarts or updates. By default, the wired M-Bus power is now disabled. Users will need to manually enable it if needed.
Affected product: Supercal 5.
Improvement : As LoRaWAN devices always have their payloads encrypted by default, the "start and end encryption" option is not applicable to these devices. We have added a note explicitly stating that "start and end encryption" is not used for LoRaWAN devices.

Affected product: All.
Improvement : You can now chose the device type from a drop down selection list, before reading it. This has the advantage, that you do not have the choose the baud rate and the communication options are already adapted to the device selected.

Affected product: All.
Improvement : We’ve unified the error and warning icons across all devices, ensuring a consistent and clear visual experience when identifying issues.
Affected product: Supercal 5.
bug fixed: We resolved an issue where LCD positions defined by customers were not correctly copied when transferring configurations between devices with different firmware versions.
Affected product: Superaqua 1.
Bug fixed: We have fixed the bug where LoRaWAN parameters were incorrectly hidden for WECOUNT-S water meter products with Manufacturer ID = WEH.
Affected product: Supercal 5.
Bug fixed: Fixed an issue where a false error message ("Unknown CI field") was mistakenly generated when reading an SC5 device.
Affected product: Superprog.
Bug fixed: Various spelling and translation errors have been corrected to improve the clarity and professionalism of the interface.
Affected product: Supercom W1-L and W2-L.
Bug fixed: The values displayed for LoRaWAN "transmission intervals" (SF7-SF12) were incorrect and have now been fixed.